Sign In | Join Free | My himfr.com
Home > Vibration Shaker Table Systems >

High Frequency 5~2,600Hz Vibration Testing Equipment Max. Velocity 1.8 m/s

    Buy cheap High Frequency 5~2,600Hz Vibration Testing Equipment Max. Velocity 1.8 m/s from wholesalers
     
    Buy cheap High Frequency 5~2,600Hz Vibration Testing Equipment Max. Velocity 1.8 m/s from wholesalers
    • Buy cheap High Frequency 5~2,600Hz Vibration Testing Equipment Max. Velocity 1.8 m/s from wholesalers
    • Buy cheap High Frequency 5~2,600Hz Vibration Testing Equipment Max. Velocity 1.8 m/s from wholesalers
    • Buy cheap High Frequency 5~2,600Hz Vibration Testing Equipment Max. Velocity 1.8 m/s from wholesalers
    • Buy cheap High Frequency 5~2,600Hz Vibration Testing Equipment Max. Velocity 1.8 m/s from wholesalers
    • Buy cheap High Frequency 5~2,600Hz Vibration Testing Equipment Max. Velocity 1.8 m/s from wholesalers
    • Buy cheap High Frequency 5~2,600Hz Vibration Testing Equipment Max. Velocity 1.8 m/s from wholesalers

    High Frequency 5~2,600Hz Vibration Testing Equipment Max. Velocity 1.8 m/s

    Ask Lasest Price
    Brand Name : Haida
    Model Number : HD-G826
    Certification : ISO
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 300 Sets per Month
    Delivery Time : 20 days after order confirmed
    • Product Details
    • Company Profile

    High Frequency 5~2,600Hz Vibration Testing Equipment Max. Velocity 1.8 m/s

    High Frequency 5~2,600Hz Vertical Electrodynamics Vibration Shaker Test Machine


    Introduction:

    Vibration Shaker Test Machine is also called vibration exciter or vibration generator.It is a device that USES electric, electro-hydraulic, piezoelectric or other principles to obtain mechanical vibration.The idea is to feed a excitation signal into a coil in a magnetic field to drive a table connected to the coil.The electrodynamic vibration table is mainly used for vibration measurement above 10Hz, with a maximum excitation pressure of 200N.In the frequency range below 20Hz, electro-hydraulic vibration table is often used. At this time, the nature of the vibration signal is controlled by the electric servo system.Hydraulic drive system can give greater displacement and impact.The vibration table can be used for accelerometer calibration, vibration performance measurement and vibration test of electroacoustic devices.For different test objects and technical indicators, attention should be paid to the selection of different structures and excitation range of the vibration table.


    Electro-dynamic Vibration Testing System Performance Data Sheet:


    Shaker (Model# EDM-2000)
    Sine force (peak)30kN
    Shock force (peak)60 kN
    Frequency range5~2,600 Hz
    Displacement (continuous)100 mm
    Max. Velocity1.8 m/s
    Max. Acceleration75 G
    Armature Diameter445 mm
    1st order resonant frequency2,400 Hz
    Allowable eccentric moment>500 Nxm
    Armature weight40 kg
    HE/ST screw dimensionM10 (metric)
    Axial vibration isolation frequency<3 Hz
    Max. Payload500 kg
    Magnetic flux leakage≤1 mT
    Dimensions (L×W×H, unpacked)1,330x860x1,250 mm
    Weight (unpacked)2,500 kg
    InstallationRubber mat (anchor bolts required)
    Power Amplifier (Model# VSA-H323A)
    Amplifier output30 kVA
    SNR>65 dB
    Rated output voltage120 Vrms
    Amplifier efficiency> 90%
    Dimensions (L×W×H, unpacked)800x900x2,100 mm
    Weight (unpacked)500 kg
    Blower (Model# PBL-W30)
    Air volume0.46 m3/s
    Power7.5 kW
    Air duct diameter200 mm
    Air pressure8.8kPa
    InstallationAble to connect to ceiling (up to two 90 degree bends), max 20’ run
    Horizontal Slip Table (Model# 30ST-600M)
    Dimensions600x600 mm
    Thickness45 mm
    Frequency limit2,000 Hz
    Effective mass54 kg

    Note:

    1. High pressure oil-film bearing is used for better uniformity.

    Vibration Controller and Accelerometer
    Vibration Controller VT-9008-44 Channel Vibration Controller with Sine and Self Calibration.
    Accelerometer EA-YD-181100mV/g, Range: 50g, Working Freq.: 1-10kHz, Weight: 11gram, with 10ft low noise cable
    Other supported functions/accessories
    Environmental chambersSupported
    Mobile devicesCustomizable
    Insulation boardsCustomizable
    FixtureCustomizable
    Working environment of the system
    Temperature range0-40℃
    Humidity range0~90% , no condensation
    Power requirements380V/3ph/50Hz, 40kVA
    Compressed air pressure0.6 Mpa

    Characteristics:

    Ultra mute work; The machine base uses the high quality material, installs conveniently, the operation is smooth, does not need to install the The, the control circuit digitization control and the display frequency, the PID adjusts the function, causes the equipment work to be more stable, reliable, sweeps the frequency and the fixed frequency operation way, adapts to the different profession test request To solve the interference of the strong electromagnetic field to the control circuit, and to increase the working time set, so that the test product reaches the accurate test time.


    How to use:

    1, the control manual to complete the procedure

    2, such as Operation error so that can not work, you can use the recovery method of the steps of the input, and then set a single group or other running steps.

    3, before use to press the external start switch, appears COO namely lets go, opens the key.

    4, Taiwan Body:

    1 The table body foot sleeve as far as possible fixed

    2 power supply on/work in the output line can not be unplugged

    3 Place the level as far as possible

    4 components can be changed, the line should not be changed or from the connection.

    5, the amplitude inside the code

    1. Do not adjust too large before or after the boot

    2) low-key amplitude of high amplitude modulation

    3 Control Panel Amplitude Knob placed in the middle position test items: placed to focus on the main point, reduce the left flat right.

    6, Inside Code:

    1) reset when running or operating incorrectly

    2) Control The Reset method step, each inside code only set one time to save can

    7, Control Box:

    1) The connecting line of the body must be locked tightly after hanging

    2 the vibration direction switch and the output connection line are correspondence, can not connect the wrong

    8, testing: Non-special test should use full wave test

    9, the Taiwan body: can not produce the collision sound, the upper and lower center axis mutual touch will cause the spring steel piece rupture to be immediately shut down, amplitude modulation is adjusted small then turns on.

    10, other unknown:

    Do not arbitrarily change internal components and lines

    11, the reason is bad:

    1 The use of computer models can not be used for shaking table control

    2 can not reload the driver

    2, for the Ista-ia test, the operator to protect the sample, to prevent the test pieces slide out of the table;

    3, gear gearbox replacement regularly;

    Electrodynamics Vibration Shaker Test Machine Images